Website page 45 Return “Printer Company” web page, Choose the corresponding provider with the printer listing and enhance the service. The method integrates motorists of HP printers, just after HP printers are related, drivers will likely be set up routinely (about 10s).If automobile set up fails, icon will Display screen on the ideal lower corner of the monitor to warn you that handbook installation is necessary. Page forty six: Network Preset
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Observe: On the check, the brightness adjustment arrives prior to contrast. Soon after readjusting the monitor’s distinction and brightness, adjust all preset and peripheral settings.
Don't use any cables besides the cables provided Along with the device by Mindray. 3. Make use of the cable delivered with this system to attach the printer. Other cables could end in electric powered shock. Web site fifteen: Mechanical Protection
Click on Concur and Move forward to accept cookies and go on to the location or click Additional information to find out in-depth descriptions of the kinds of cookies and select regardless of whether to accept selected cookies when on the internet site.
Articles Strategy Look at the battery periodically : a) Look at if battery might be billed Ordinarily when electric power-on: That The present ability is 100% or capacity will increase after a short time suggests that the battery could be charged Commonly.
Website page 145 Thoroughly clean control panel Instruments: dry comfortable fabric, moderate soapy h2o Approach: Use dry smooth fabric to wash the area of the procedure. Should the system is soiled, moisten the comfortable fabric with moderate soapy h2o and wipe off any stains. Use dry gentle fabric to remove any moisture and allow all really hard surfaces to completely air-dry. Webpage 146: Cleanse The Peripherals
Explore greater diagnostic information and facts by prolonged watch of your anatomical composition on all convex probes.
iZoom™ allows accurate viewing of picture from distance iWorks™ Protocol allows standardize workflow and decrease Test moments
5.2.3 Geometric positioning precision Longitudinal geometric positioning accuracy Take a look at Phase: Do changes as the way in screening the utmost depth. File the gap by 20mm Every segment to the longitudinal targets line using the measurement caliper; Find the value with the best mistake (to 20mm), work out the accuracy using the components below The measurement caliper need to be positioned with the upper fringe of the concentrate on, Take note:... Web site seventy nine Transverse geometric positioning precision Test Action: Cover the scan surface with the phantom with water or few gel, Carefully Get hold of the probe With all the scan area Change the depth, producing the transverse targets to become exhibited within the picture. Adjust the main focus position to become posited beside the transverse targets (the common will not be apparent) Alter parameters like attain, TGC, producing Every single transverse targets for being Evidently shown. Site eighty 5.five.2.4 Blackout Region Check Step: Address the scan floor of the phantom with h2o or couple gel, gently contact the probe While using the scan surface Regulate the depth at a decreased value, and set the main focus at the nearest spot to the scan surface. Minimize the worth of parameters like AP, Obtain till the Dp50rb background noise just can be seen. Website page eighty one: Software Up grade And Maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
.. Page 161 The indicator around the printer Mistakes take place once the adapter turns orange, along with the printing printer adapter operates. Disconnect and hook up the fails. electric power adapter, electric power over the printer adapter once more, and verify whether or not the printing is typical soon after 1 moment. Web page 163: Electrical Basic safety Inspection
Overall performance Take a look at 5.five.one Check Procedure Resolution Detection depth Geometric Position Precision Blackout region exam File the Test illustrations or photos 5.5.two Test Written content The impression used Here's just for reference, stick with the graphic influence in the real Observe: circumstance. Requirements: Display screen: established the contrast and brightness for the medical application benefit (or maybe the default standing) Operation surroundings: dark home, simulating the scientific application atmosphere. Webpage seventy six In problem which the transverse resolution tests targets are horizontally displayed, history the nominal length of two targets which might be clearly regarded. Repeat the operation above to the transverse resolution screening targets at other depths. As demonstrated in figure under. Axial resolution ... Web page 77 When utilizing the convex probe, hold the transverse resolution testing targets to NOTE: be displayed close to the midline. When using a linear probe with steer operate, do not activate the steer purpose when conduct the transverse resolution take a look at. Zoom while in the area the place the targets Situated if necessary. The diameter of the concentrate on stage at a particular depth is equal towards the transverse resolution on the depth. Website page 78 five.
After changing the CPU module, critical file need to be created Again based on the new MAC tackle and created into HDD with the equipment. Or else, the configuration perform of the item will likely be dropped. Soon after taking away the CPU module, Eliminate panhead screws with washers (twelve M3X6) mounted on the principle unit box, you usually takes off the board. Web page 118 Determine 8-29 Disassemble the User interface Assembly (1) Keep the upper edge of user interface assembly, and open up up the user interface. Determine eight-30 Disassemble the Control Panel Assembly (2) Following getting rid of 1 countersunk head self-tapping screw PT3X10 fastened around the control panel and just take out the plug of your keyboard and the key unit connecting cables, you could potentially eliminate the control panel assembly.
A wise new condition, Improved mobility and easy operation make DP-fifty like minded for all clinical settings.